Description
Product Introduction:
[Data Storage and Export]: The data of this graphic oscilloscope meter can be saved and exported to your flash drive, computer, PC, etc.
[Rechargeable]: The handheld oscilloscope multimeter comes with a rechargeable battery and charging cable, ensuring that you never have to worry about running out of power during the measurement.
[Carrying case]: The digital oscilloscope multimeter comes with a high-quality EVA carrying case, which is perfect for use on the go.
Multimeter Function Comparison |
||||||||
|
Model |
O7 |
O9 |
||||||
|
Function |
Range |
Resolution |
Range |
Resolution |
||||
|
DC Voltage(V) Accuracy |
1000V 0.001V |
1000V 0.0001V |
||||||
|
DC Voltage(mV) Accuracy |
600mV 0.01mV ±(1.0%+5) |
200mV 0.01mV |
||||||
|
AC Voltage (V) Accuracy |
750V 0.001V ±(1.0%+3) |
750V 0.0001V |
||||||
|
AC Voltage (mV) Accuracy |
600mV 0.001mV ±(1.2%+5) |
200mV 0.001mV ±(1.2%+5) |
||||||
|
DC Current(mA) Accuracy |
600mA 0.01mA |
200mA 0.01mA ±(1.0%+3) |
||||||
|
AC Current(mA) Accuracy |
600mA 0.01mA ±(1.2%+5) |
200mA 0.01mA |
||||||
|
AC Current(A) |
6000A(Need Flexible Current Clamp) |
2000A(Need Flexible Current Clamp) |
||||||
|
Resistance Accuracy |
60MΩ 0.001MΩ |
200MΩ 0.0001MΩ |
||||||
|
Capacitance |
99.99mF 0.001mF |
99.999mF 0.001mF |
||||||
|
Temperature |
-20~1000℃ |
-20~1000℃ |
||||||
|
Display Value |
6000 Counts |
20000 Counts |
||||||
|
Diode |
√ |
Connectivity |
√ |
|||||
|
True Virtual Value |
√ |
Screen Backlight |
√ |
|||||
|
Low Battery Reminder |
√ |
Auto Power-off |
√ |
|||||
|
Size |
216.6*84.5*36mm |
Weight |
384g |
|||||
|
Type Of Battery |
18650 Battery 3000mA*2,6000mA Long Endurance |
|||||||
|
Screen |
3.98-inch TFT full-view color screen |
|||||||
|
|
|
|
|
|
|
|
|
|
Oscilloscope technical index comparison |
||||
|
Character |
Instructions |
|||
|
Bandwidth |
O9:50MHz |
Dual channel real-time sampling |
||
|
O7:25MHz |
||||
|
Sampling |
Sampling mode |
Real-time sampling |
||
|
Sampling rate |
O9:250MSa/s |
|||
|
Channel |
2 |
Dual channel DC, AC |
||
|
INPUT |
Input coupling |
DC/AC |
||
|
Input impedance |
1MΩ,@16pf |
|||
|
Probe attenuatior |
×1,×10 |
|||
|
Maximum input voltage |
X1 range <150V, |
|||
|
Horizontal |
Sampling rate rang |
O7 |
|
|
|
Waveform interpolation |
(sinx)x |
|||
|
Sweep range |
100ns/div-20s/div |
|||
|
Time base accuracy |
20ppm |
|||
|
Storage depth |
128Kbyte |
|||
|
Vertical |
Sensitivity |
20mV/div-10V/div |
||
|
Displacement range |
4 squares (plus or minus) |
|||
|
Analog bandwidth |
O7:25MHZ |
O9:50MHZ |
||
|
Frequency response |
>10HZ |
|||
|
Rise time |
<10ns |
|||
|
DC gain accuracy |
± 3 % |
|||
|
Measure |
Automatic |
Period, Frequency, Peak-to-Peakvalue, Maximum value, Minimum value, Duty cycle, Root meansquare |
||
|
Trigger |
Trigger mode |
Auto, Normal, Single |
||
|
Trigger edge |
Rising edge, Falling edge |
|||
|
Display mode |
YT, XY, RoII |
|||
|
Afterglow time |
Minimum, 500ms, 1S, 10S, Unlimited |
|||
|
Waveform Type |
Sine wave, Square wave,Triangular wave, Half wave,Full wave, Sawtooth wave, DC |
|||
|
Frequency Range |
Sine wave: 0HZ-5MHZ; full wave, sawtooth wave, DC: 0HZ-2MHZ |
|||
|
Channel |
1 |
|||
|
Output Amplitude |
0.1V~3.0V |
|||
|
Resolution |
1HZ |
|||
|
Square-wave Duty Cycle |
1%~99% |
|||
|
Oscilloscope Mode Main Screen Description |
||||||
|
No. |
Name |
Instructions |
No. |
Name |
Instructions |
|
|
1 |
Trigger channel |
CH1 is channel 1, and CH2 is channel 2 |
14 |
Vertical flip-flop |
Vertical voltage position triggered |
|
|
2 |
Running status |
Status: Stop/Run |
15 |
Horizontal trigger |
Horizontal timebase position of the trigger |
|
|
3 |
Ch1 |
CH1 waveform is displayed in yellow |
16 |
CH1 Parameters |
Specific parameters of CH1 |
|
|
4 |
Ch2 |
CH2 waveform is displayed in blue |
17 |
CH2 Parameters |
Specific parameters of CH2 |
|
|
5 |
Channel switch |
CH1/CH2 On-off state |
18 |
Voltage/Time base menu |
Press up key to increase the voltage amplitude, |
|
|
6 |
Attenuation |
Channel attenuation factor |
||||
|
7 |
Voltage scale |
Vertical voltage scale value |
||||
|
8 |
Time base |
Timebase position in storage depth |
||||
|
9 |
Time base scale |
Horizontal time base scale value |
19 |
Wave movement |
Press the up/down button to adjust theupper and lower positions of the waveform, |
|
|
10 |
Wave Mode |
Auto/Normal/Single |
||||
|
11 |
Trigger mode |
Rising or falling edge |
20 |
Trigger cursor |
Press the up and dow keys to adjustthe position of the trigger cursor |
|
|
12 |
Battery level |
Battery status and charging status |
21 |
Measuring cursor |
Press F4 to switch the measurement cursorselection, |
|
|
13 |
Trigger level |
Trigger voltage value |
||||
|
Multimeter Mode |
||||||
|
No. |
Name |
Instructions |
No. |
Name |
Instructions |
|
|
1 |
Battery level |
Displays the battery status and charging status |
8 |
Auto shutdown |
Displays the time to set automatic shutdown |
|
|
2 |
Main display |
Display multimeter measurements, |
9 |
Peak mode |
Press PAEK switch to peak mode(this mode is only valid for AC voltage) |
|
|
3 |
Mode |
Measurement mode |
||||
|
4 |
Range |
Current mode range |
10 |
Maximum value |
Displays the maximum read value |
|
|
5 |
Auto range |
Automatic range switching |
11 |
Minimum value |
Displays the minimum read value |
|
|
6 |
HOLD |
Press SAVE key to pause the data display |
12 |
Average value |
Displays the average value |
|
|
7 |
Mode |
Display the current selected measurementmode is highlighted red.Press the left, right.up, and down arrow keys to switch gears |
13 |
Terminal prompt |
Displays the terminal to be selected for current mode |
|
|
14 |
Unit |
Displays the unit of the measured data |
||||



















Specification:
Maximum display: 20000 count screen
Size: 3.9 inches
Bandwidth: 50MHz
Real-time scanning rate: 250MSa/s
Input impedance: 1MΩ
Maximum Input Voltage: ×1 Range<150V, ×10 Range<300V (DC+AC Peak)
Horizontal seconds range: 100ns/div -20s/div
Vertical sensitivity: 20mV/div -10V/div
DC voltage: 20mV 0.001mV ± (1%+5); 200mV/2V/20V 0.01mV/0.0001V/0.001V/ ±(0.8%+3); 200V/1000V 0.01V/0.1V ±(1%+5)
AC voltage: 20mV 0.001mV ± (1.2%+5); 200mV/2V/20V 0.01mV/0.0001V/0.001V/ ±(1%+3); 200V 0.01V ±(1.2%+5); 750V 0.1V ±(1.2%+5)
DC current: 20mA/200mA 0.001mA/0.01mA ±(1%+3)
AC Current: 20mA/200mA 0.001mA/0.01mA ±(1.2%+5)
Flexible Current Clamp AC Current: 200A/2000A 0.1A/1A ±(1%+5)
Resistance: 200Ω 0.01Ω ± (1.2%+5); 2K Ω/20K Ω/200K Ω 0.0001K Ω/0.001K Ω/0.01KΩ ±(1.0% + 3); 2MΩ 0.0001MΩ ±(1.2% + 5); 20MΩ 0.001MΩ ±(1.5% + 5); 200MΩ 0.01MΩ ±(1.5% + 5)
Capacitance: 999.9nF 0.01 nF ± (5% + 20) 9.999 μF/999.9 μF 0.001 μF/0.01 μF ± (4.5% + 5); 99.99mF 0.001mF ±(5.0%+10)
Temperature: -20~1000°C/-4~1832°F 1°C/1°F ±(2.5% + 5)
Diode: Yes
Continuity: Yes
Power supply: 5000mA
Size: 216.6x84.5x36mm
Weight: 384g
Package includes:
1 x Handheld Oscilloscope Multimeter
1 x EVA suitcase
2 x oscilloscope probes
1 x Oscilloscope Accessory
1 x multimeter pen
1 x Crocodile Clip
1 x box
1 x charging cable
1 x Instruction Manual
1 x warranty card
1 x User Manual
We are here to help!
If you are having any trouble with locating the correct replacement, part number, or assistance with diagnosis please do not hesitate to reach out to us.
Support